<LOGO>
FM Transmitter Measurement Report
Created: 2026-05-02 03-42-56
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.70 MHz 4/5, 48 dBuV THE
Pilot RDS Phase Difference
6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 54 kHz 2313 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 2,50 dBr 3,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" THE " 4F14 10 (Pop M) 1 0 1 1 --:--
RT
" So tönt Abwechslung - Radio Zürisee "
AF EON
88.4, 90.2, 100.4, 104.7, 106.7, 107.4 MHz -
FM Scope Max at: 54 kHz MIN: 12 kHz % above 76 kHz: 0,0000 Acquired: 2026/05/02 3.41.52 Total samples: 2313 Equivalent time: 0:01:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200